An example of a wiring diagram for a motor controller
|
| |
Date:2010-01-29 23:51:27Click:292Comment:0
|
| A control system will normally use AC and DC power at different voltage levels. Control cabinets are often supplied with single phase AC at 220/440/550V, or two phase AC at 220/440Vac, or three phase AC at 330/550V. This power must be dropped down t |
|
 |
The cable layout of Omron PLC connected to peripheral equipments
|
| |
Date:2008-05-21 04:13:50Click:814Comment:0
|
| The PLC's from Omron can be connected to various peripheral equipment. Each device requires its own cable layout. Only the more common cables are shown here. DB9 RS232 programming cable DB25 RS232 programming cable CV500-CIF01 toolbus programming ca |
|
 |
CPM2A plc and a NT11 problem and answer
|
| |
Date:2008-02-26 07:55:35Click:287Comment:0
|
| Q: Ihave a CPM2A plc and a NT11 pt.I have read in the NT11 instruction manual that when numerical data is input at the NT11, this is automatically notified to the PT status notify area allocated in the PLC memory as follows. I set the notify area to |
|
 |
How fast is Ethernet really in Industrial Automation Engineering ?
|
| |
Date:2007-12-11 23:52:18Click:124Comment:0
|
| Authored By Jeff Nowling Industrial Automation Engineering Consultant, Omron Electronics LLC With the popularity and low cost of Ethernet hardware, industrial control systems are evolving toward this platform. Users be aware; proper network design a |
|
 |
OMRON Remote PLC Communications Guide
|
| |
Date:2007-12-11 23:50:42Click:4898Comment:0
|
| Written by Jay Hughes 1-1 Introduction Welcome to OMRON Electronics LLCs Remote PLC communications guide. The purpose of this guide is to allow remote programming monitoring, and diagnostics of OMRON PLCs. This is accomplished by connecting a modem |
|
 |
FAQ of LSS Ladder Support Software
|
| |
Date:2007-12-11 23:48:03Click:249Comment:0
|
| 1. LSS software locks up during the initialization period whenever I install the software. Why? Answers: Check to see if computer has a CD-ROM drive. 1.) Reboot computer with CD-ROM drivers removed. 2.) Install the LSS software. 3.) Reinstall ROM dr |
|
 |
Can LSS have more than 1 library file?
|
| |
Date:2007-12-11 23:47:04Click:68Comment:0
|
| Yes. Normally LSS creates library files as PGC2000.DAT or PGC500.DAT, depending on the model PLC you are programming for (see the answer to question 5 for more details). Once a library file has been created you can use the DOS RENAME command to rena |
|
 |
How can I delete vertical lines
|
| |
Date:2007-12-11 23:45:22Click:43Comment:0
|
| Place the cursor at the bottom right of the vertical line you want to delete. Make sure you are in write mode (F2) then press F6 (for vertical line) then press the backspace key. The line should now have been deleted. |
|
 |
When printing a ladder diagram, why aren’t the comments printed?
|
| |
Date:2007-12-11 23:43:43Click:42Comment:0
|
| To print a ladder diagram with comments LSS must be set to print in one of two graphics modes. To check this, go to the SETUP menu and select the PRINTER option. From this there are three settings that may be made - to print comments one of the two |
|
 |
Installing and Running Omron LSS3 software
|
| |
Date:2007-12-11 23:37:16Click:811Comment:1
|
| PRODUCT: LSS version 3.02. WHAT IT DOES: LSS (Ladder Support Software) is a software package used for writing and documenting ladder programs for the C-series PLCs. LSS will run on any IBM PC or 100% compatible under DOS 3.20 or higher. The installa |
|
|
 |
|